Related Articles |
SKELETAL MUSCLE ULTRASOUND: CORRELATION BETWEEN FIBROUS TISSUE AND ECHO INTENSITY.
Ultrasound Med Biol. 2008 Dec 9;
Authors: Pillen S, Tak RO, Zwarts MJ, Lammens MM, Verrijp KN, Arts IM, van der Laak JA, Hoogerbrugge PM, van Engelen BG, Verrips A
Abtract- In this study, we examined the correlation between muscle ultrasound and muscle structure. Echo intensity (EI) of 14 muscles of two golden retriever muscular dystrophy dogs was correlated to the percentage interstitial fibrous tissue and fat in muscle biopsy. A significant correlation between interstitial fibrous tissue and EI was found (r = 0.87; p < 0.001). The separate influence of interstitial fat on muscle EI could not be established as only little fat was present. We conclude that fibrous tissue causes increased muscle EI. The high correlation between interstitial fibrous tissue and EI makes ultrasound a reliable method to determine severity of structural muscle changes. (E-mail: s.pillen@cukz.umcn.nl).
PMID: 19081667 [PubMed – as supplied by publisher]